Technical Parameters:
1, The test must be carried out in a 10 ° C ~ 32 ° C ambient temperature, with exhaust ventilation in a closed room.
2, Power supply: AC 220V+ 10%/50Hz.
3, The test flame gas source using gas or liquefied petroleum gas (it is recommended to choose a better gas).
4, Burner specifications: inner diameter: 50 + 0.5mm (60.3mm).
5, The length of the burner: 1.120 + 0.05m, and with a width of 12.7mm long 910mm long jet hole. Both ends of the gas input to maintain uniform pressure in the tube.
6, The flame of the solar panel combustion tester can be easily adjusted through the adjusting valve, which can be adjusted from 150mm to 300mm; the flame application time and interval time can be preset.
The flame application time and interval time can be preset.
7, With flame measuring tools: including copper block, thermocouple, temperature table and pure stainless steel flame length gauge, 20 ° angle gauge and so on.
8, With gas flow meter and pressure gauge, regulator, etc..
9, The test platform: test materials placed therein, the size of about 1300x 1000mm (the actual size of the test specimen according to the different gap will be partially filled).
10, The platform test installation angle: maximum 127 (height) / 300 (length); simulation of eaves and test bench tail panel (non-combustible materials). Solar panel combustion testing machine test air box: dimensions of about 762 high x width 2130 x length of at least 2500mm, and designed to regulate the blade, to ensure that the air ducts to send wind uniformly, does not produce turbulence.
11, Fan: air volume of about 200 ~ 1000m3 / min, using frequency conversion to adjust the air volume. Equipped with hot air anemometer. With length gauge, 0~1000mm±1mm, and tape measure 5m±1mm.
12, Dimensions and weight of fuel block.
 A: 300x 300x19.1x 3mm, 2000±150g.
 B: 15x150x19.1x3mm, 500 ±50g.
 C: 38.1 x38.1x 19.8mm, 9.25±0.2g.
13, It is recommended to choose the combustion gas alarm device, to prevent gas leakage may be bow|upon the harm.
14, Solar panel combustion testing machine should be prepared before each test mortar required to fill the gap.