Products

Building material flame retardant tester

Item No.: SH5709
The tester is designed for the testing of building materials according to DIN 4102-1 and is used to determine whether a material is flame retardant or not. The tester consists of combustion chamber, burner and control instrument. The combustion chamber co
INQUIRY
Description
Building material flame retardant tester
The tester is designed for the testing of building materials according to DIN 4102-1 and is used to determine whether a material is flame retardant or not. The tester consists of combustion chamber, burner and control instrument. The combustion chamber consists of five parts: combustion chamber, burner, specimen holder, air stabilisation layer and flue. It is equipped with computer system to realise measurement and control and data processing.

Technical Parameters
1, Power supply: single-phase 220 ± 10% V, 50 HZ, power about 15 KW
2, Test furnace size: 1020x 1020x 3930mm.
3, Burner: 200x 200x in 3.5mm
4, Temperature sensor adopts nickel-chromium-nickel-silicon armoured thermocouple with filament diameter of 0.5mm and external diameter of not more than 3mm and accuracy of class I.
5, When the average flue gas temperature exceeds 200°C, the equipment will stop supplying fire automatically.
6, Gas flow and air flow using high-precision flow sensors, range: 0.25-2.5m3 / h, through precise control and adjustment of gas and air flow, can achieve the temperature and accurate control.
7, The furnace pressure using 0.5 high-precision pressure sensor sampling supporting the corresponding data collector, computer real-time monitoring and displaying the pressure change curve.
8, Furnace test pressure: (-15 ± 10) Pa
9, Constant temperature and constant flow air supply system: .
10, the air flow in the furnace (using frequency control fan): 5-15 m3 / min adjustable, adjustable to the standard requirements of the average value: (10 ± 1) m3 / min.
11, Temperature: 23 ° C + 2 ° C combustion chamber
12, Diameter of air inlet pipe: in 200mm
13, Combustible gas: purity greater than 95% of the methane
14, Test methane flow: (35 ± 0.5)L / min
15, Test air flow: (17.5±0.2)L/ min 
16, Timing: 1 ~ 99 min can be set.
17, Accompanied with high-precision hot-ball anemometer, accuracy better than ±10%.
18, With 4 pieces of 1000m m *190 mm *3 mm stainless steel plate
19, Computer type: DELL, dual-core processor, 19-inch LCD monitor, hard drive 160G, DVD burning optical drive.
20, Using computer control, high degree of automation, real-time display of the test process data and graphs and can be stored and printed.
21, Supporting the corresponding data collector computer real-time monitoring and display of temperature change curve.
22, Windows operating system user-friendly interface, free to set, control and display the test time and smoke density test curve, automatic calculation of smoke density level, can be stored and printed.


 
Review


1/3
X