Rang Hood Air Flow Test Device

Item No.: SH9613
The device is designed according to the relevant standards requirements of IEC60665, IEC61591 and other corresponding provisions. 
INQUIRY
Description
Aerodynamic performance testing device
 
      The device is designed according to the requirements of IEC60665, IEC61591 and other relevant regulations. 
   
      The device is suitable for the aerodynamic performance, air flow test of an range hood hood.

      This device can measure the performance indicators such as air volume and air pressure (micro differential pressure) of the device under test, and choose to test the ambient temperature and pressure. Usually, the sampling points are located at 4-8, but can be individually identified according to the customer or the actual situation. The time interval for each change of working status is usually within 50S.

       If a software system is used, it can also be converted to a tester with a large amount of air pressure and efficiency indicators. It can also be based on test data to fit the characteristic curve.

 

Test chamber requirements: 
  1. Temperature range: 15 to 35, relative temperature: 25 to 75%
  2. Power supply: AC 3 phrase /415V 50HZ  Power: 5KW  
  3. Air volume range: 0.8-25m³/min, measuring accuracy ±2;
  4. Micropressometer range: 10-700 Pa;
  5. Accuracy:±0.2%FS
  6. Atmospheric pressure sensor accuracy of: ±0.67 Pa.
  7. Temperature range: 10-50 with ± measurement accuracy.
  8. Power range: 10-500W with ± (0.3% RD + 0.2% FS) test accuracy.
  9. Time range: 0-99.99 H, measurement accuracy:0.1S.
  10. Equipped with a centralized computer measurement and control system, which can be switched to a different test program each time according to different type of product (only one specification can be tested at a time).
  11.  Air volume and performance test specification device, matching test A, B and C type combinations.
  12. Bulkhead type (Type A) consists of: booster fan, 2 resistance grids, rectifier, connector and orifice plate.
  13. Free inlet type (type B) consists of: connector, cross-type rectifier, pressure reducing cylinder, regulator and orifice plate.
  14. Free exhaust type (type C) consists of: orifice plate, decompression cylinder, connector and cross rectifier.
  15. Main body support, pressure equalization chamber.
  16. Flow nozzles in sets of approx. 5-6 sizes (depending on the actual air volume). Regulate according to the system settings.
  17. Connectors (5 sizes), (dimensions to be provided by the customer).  Micro differential pressure sensors atmospheric, pressure sensors
  18. Test instruments for temperature, power, etc.
  19. I/O interface board, acquisition module system (configuration for computer acquisition and processing required)
  20. Voltage regulator: 1KVA (±2 Domestic)
  21. Power meter Domestic single-phase electric parameter meter (0.5 level)
  22. Control cabinet and low voltage electrical appliances.
  23. Computer (commercial computer, with SANS plug), laser printer, CPU power supply Software(English version)
  24. Software display the change curves of all parameters in real time, automatic coordinate changes, and at the same time enlarge and print various combinations of curves and experimental reports in real time.
  25. All curves and reports are automatically saved and the curves and data of all tests can be queried through the query system.
  26. Software automatic calculation and calibration parameters and measurement and printing functions.
  27. Equipment has protection for temperature, voltage, current and other abnormalities.
  28. Organic material: flame-retardant.
  29. Orifice plate of the air volume test device selected manually.
  30. Electrical safety design meets the requirements of the relevant national standards.