Technical Parameters:
1. Power supply: AC220V ± 10% / 50Hz.
2. The inner diameter of the tube of the igniter is 11mm, and the tube head is 25 ° with a vertical line.
3. Ignitor timing: 0 ~ 99min 99s can be set arbitrarily; afterburning time and flame retardant timer: 0 ~ 99min 99s, accuracy: ± 0.1s.
4. Flame height measuring device: the height of the scale is 40mm ± 2mm.
5. The inlet gas pressure is 17.2 ± 1.7kPa.
6. Gas used: propane or butane or petroleum liquefied gas.
7. Sample size: 300mm × 80mm.
8. Heavy hammer weight: select according to the variety and quality of the test product. (Optional combustible gas leakage alarm device)