Technical Parameters:
1. Equipment power: AC 220V 50Hz.
2. Equipment air source: 6 ~ 8kg / cm2.
3. Switch-on time: 0.5 ~ 9.9 seconds (minutes) (adjustable).
4. Test cycle time: 0 ~ 99 seconds (adjustable).
5. Counter: 0 ~ 99999 times can be preset (counted by sampling current of the tested product). It has the function of logical judgment of damage in the sample test).
6, test station: 2 stations (each station has a separate controller and reset function).
7. Pull wire test angle: 0 ~ 45 ° (adjustable), scale at 30 °, pull wire switch installed horizontally, Move the head in the horizontal direction to adjust the pull angle.