Products

Thermally protected lamp controlgear abnormal circuit tester

Item No.: SH3324
The test device is designed according to IEC 60598-1-2014 Appendix C, GB 19510.4-2009 Article 16 and the requirements of Standard Figure 1 and GB 19510.13-2007 Article 17 and the requirements of Figure 2, IEC 61347-1 Annex B, IEC 61347-2-3 Section 15,16.
INQUIRY
Description
Test device is designed according to IEC 60598-1-2014 Appendix C, GB 19510.4-2009 Article 16 and the requirements of Standard Figure 1 and GB 19510.13-2007 Article 17 and the requirements of Figure 2, IEC 61347-1 Annex B, IEC 61347-2-3 Section 15,16.
Technical parameters.
  1. Contains 3 circuits C1 C2 C3
  2. Power: > 1000W
  3. Adjustable resistance: 0 to 200.00Ω, can carry current 1A
  4. Resistance value error: 3%
  5. Voltage accuracy: 0.1V
  6. Current accuracy 0.01A
  7. Diode D:100A,600V
  8. The characteristics of the rectifier tube are described below:
  9. Reverse peak voltage URM ≥ 3000 V
  10. Reverse leakage current IR≤10μA
  11. Forward current IF ≥ three times the nominal operating current of the lamp
  12. Reverse recovery time 
  13. (Maximum frequency: 150 kHz) (Measurement conditions: IF=0.5A, and IR=1 A to lR=0.25 A)
  14. Includes dedicated circuit box.
  15. Environment of use
  16. Power supply conditions: AC 220V±10%, 50 Hz.
    Operating temperature 15~40℃
    Relative humidity ≤85%
Review