Foam Plastic Vertical Burning Materials Test/Testing Equipment
Technical parameters:
1. Power supply: AC220V+10%/50Hz.
2. Gas or liquefied petroleum gas is used as the source of test flame (gas with better gas quality is recommended).
3. Each burner is left and right, and the distance between the burner nozzle and the test plate is 30 mm.
4. The diameter of burner nozzle is 40 +1 mm, and the inner diameter of nozzle hole is 2.5 +0.1 mm.
5. With temperature display, the temperature state of the test can be measured. The temperature of the test is 800 30 C.
6. Each K-type thermocouple has a distance of 5 mm from the temperature measuring point.
7. The flame application time and holding time can be adjusted in the range of 0-99 minutes and 99 seconds.
8. Automatic control of test process.
9. Weights 7N,10N, 12N, 15N, 17N, 20N.
10. Fume hood larger than 2 m3.