Laboratory Diet Fume Purification Equipment Materials Detection Device
Technical Parameters:
1. Power supply: AC380V, 50Hz.
2. Air volume range: 2000 ~ 20000m3 / h.
3. Oil fume generating device: It adopts automatic oil and water flow distribution and heating and evaporation automatic adjustment control system. The amount of oil fume generation can be adjusted to ensure that the average oil fume density within 10 minutes does not exceed 5%; the detection reference concentration is 10 mg / m3.
4.Detection by sensors: micro differential pressure, atmospheric pressure, flow; distance elbow, reducer ,etc.A sampling hole is provided at a diameter 1.5 times downstream of the pipe fitting.
5. Air volume adjustment system: Manually adjust the air door and frequency conversion technology.
6. Air duct: It is designed according to the air duct with a diameter of 0.6 meters (can reach the wind speed required by the standard). Front and rear air ducts (including straight and curved roads), purifier interface flanges (five specifications, the rest are customized), the air duct is made of stainless steel
7, laboratory size requirements: at least 12mX3. 5m.
8. With safety monitoring, alarm and status analysis reminding functions.