Universal Electrical Automatic Capacitor Self-Healing Test Device
Technical parameters:
1. Power supply: AC 380V ± 10% 50Hz.
2. Voltage: AC 500-1750v continuously adjustable, accuracy: ± 3% (specific parameters customized).
3. Maximum test capacitance: 100 μ f (customized).
4. Accuracy: voltage: ± 3%; current: ± 5%.
5. Inductance compensation: 100 μ f equivalent (customized).
6. Capacity: 25KVA.
7. Breakdown sound light alarm, high voltage automatic removal. Continuous test can be set for self-healing capacitor.
8. The number of self-healing breakdown was detected by pulse test.
9. Time setting: continuous or 1-99s arbitrary setting.
10. Voltage rise and fall speed: 100-200v / min. It can be raised from zero to test voltage.
11. Breakdown times: 0-9 times can be set (during self-healing test).